<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>10062</ErrorNumber>
<ErrorFamily>Hardware</ErrorFamily>
<ErrorMessage>
HARDWARE: External Debris Blower Filters Almost Full (Vacuum Level %d is below %d)
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>All</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
The vacuum sensor at the debris nozzle is reading lower than normal.  It has dropped below the
value specified in "sys dblw".  The low vacuum level is displayed as part of the error message,
as is the warning level.
</text></DescriptionText>
<DescriptionText><text>
This probably indicates that the filter is almost full and should be replaced.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
The device thinks the debris filter inside the debris cabinet is nearly full.  Open the cover of the
cabinet and replace the filter.  If the problem comes back, contact the CreoScitex Response Centre.
</text></DescriptionText>
</OperatorAction>
<Cause>
Filter is almost full.
</Cause>
<Cause>
Hoses or sensor lines not connected or are leaking.
</Cause>
<Cause>
Failure of analog board/jumper.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../commands/dr.xml</LinkAddress><LinkTitle>Command: dr</LinkTitle></Link>
<Link><LinkAddress>../nvs/sys_cfg_dblw.xml</LinkAddress><LinkTitle>NVS: sys dblw</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:32:31 2008 PST
</Updated>
<Links>
</Links>
</Error>